Loading condition | Bolt No. location | Bolt elongation λ1 [µm] | Plate compression λ2 [µm] | Total Σλ [µm] | Fa [kN] | Fb [kN] | Fc1 [kN] | Fc2 [kN] | Fd [kN] | Pmax [MPa] |
Pre-tightening by force | 1 | 246.7 | 71.5 | 318.2 | 144.71 | 144.71 | 144.71 | 144.71 | 144.67 | 195.70 |
2 | 246.6 | 71.9 | 318.6 | 144.71 | 144.71 | 144.71 | 144.71 | 145.31 | ||
3 | 246.5 | 76.9 | 323.3 | 144.71 | 144.71 | 144.71 | 144.71 | 144.53 | ||
4 | 246.7 | 77.0 | 323.7 | 144.71 | 144.71 | 144.71 | 144.71 | 144.33 |